High-performance
K-One gold bioconjugates

Discover our premium-quality gold bioconjugates and redefine your standards.
Leveraging Kimialys’ proprietary surface chemistry, K-One, we develop, manufacture, and supply high-performance gold bioconjugates optimized to your biomolecules and applications. K-One provides full control over surface interactions and protects against non-specific binding, ensuring sensitive, reliable, and reproducible results, without trading one parameter off against another.
Our bioconjugates selectively capture target molecules to enable detection assays as well as extraction, enrichment, and depletion workflows, supporting diagnostic and biopharma companies across analytical applications including bioanalysis, molecular diagnostics, immunogenicity testing, clinical chemistry, and point-of-care testing.

We position ourselves as a strong alternative to conventional gold, magnetic, latex and luminescent nanoparticles for today’s most demanding assays.
For many use cases, conventional approaches perform perfectly well. But when targets are present at very low concentrations and require pushing for higher sensitivity, this often comes at the expense of reliability and reproducibility:

  • Unprotected surfaces → prone to NSB due to the absence of protective surface chemistry.
  • Steric hindrance (beads) → particle size restricts target accessibility and reduces binding efficiency.
  • Surface overloading → saturating surfaces with ligands is costly, poorly controlled, and introduces variability and background noise.

Benchmark of nanoparticles

The state of the industry.

Gold nanoparticles are widely employed in passive form for LFA or colorimetry, valued for their ease of use and clear visual signal.

Magnetic beads have long been the industry standard for targeted capture and extraction, thanks to their robustness and compatibility with automated platforms.

Latex beads, on the other hand, are widely used in turbidimetry and nephelometry, valued for their ease of use and strong light-scattering properties. They are also available in multiple colors for straightforward multiplexing and in fluorescent variants that deliver higher sensitivity.

Luminescent nanoparticles, such as quantum dots (QDs) and up-conversion nanoparticles (UCNPs), are the latest generation of nanoparticles. They represent a high-investment technology, valued for their very high sensitivity and their narrow emission spectra that enable advanced multiplexing.

K-One gold nanoparticles are designed for challenging assays where targets are present at very low concentrations, where achieving high sensitivity without compromising on non-specific binding, background, or reproducibility is essential.
Ultimately, K-One lowers assay costs in two ways: by reducing ligand consumption (up to 30× less), as controlled orientation and density avoid the need to saturate the surface; and by reducing assay material use, as we achieve high reliability and reproducibility, avoiding the need to repeat experiments.

CriteriaStandard gold NPsMagneticLatex (colori)Latex (fluo)Luminescent (QDs, UCNPs)K-one gold NPs
Theoretical sensitivity++++++++++++
Exploitable data (sensitivity + low background + reproducibility)++++++++++++ -> Surface protection
Global assay cost*++++++++++++++
Automation compatibility-+++++++--
Multiplex color capability--++++++++-

Table: Performance of K-One gold nanoparticles compared to standard nanoparticles and beads.

* Ligand consumption, assay materials, readout equipment… — ++++ = cheaper (excluding Kimialys customization fees).

Their biomolecules are in the right hands:

Applications where our K-One gold nanoparticles make a difference

Point-of-care testing (POCT)

Lateral flow assays (LFA)

LAMP-LFA

Nanoparticle-based signal amplification

Bioanalysis

Immunoprecipitation (e.g. IP–MS, ADC–DAR, IP–Western)

Immunodepletion for interfering molecules (e.g. HSA)

Immunogenicity testing (e.g. depletion of ADA)

Molecular diagnostics

PCR workflows (immuno-PCR, qPCR, dPCR, multiplex PCR)

Isothermal amplification (LAMP)

Clinical chemistry

Turbidimetry / Nephelometry

Colorimetry

Rocket pictogram

Immobilize your ligands, not your research.

Schedule a meeting
Thumbs up pictogram
Why should I work with Kimialys?
infinite pictogram symbolizing limitless

High sensitivity

Increase your analytical sensitivity by up to 10× compared to conventional bioconjugates.

Medal pictogram to symbolize performance

High selectivity

Drastically reduce your non‑specific binding and false results thanks to K‑One surface protection.

Stars pictogram to symbolize improvement

High reproducibility

Obtain accurate, reproducible results across complex samples, including blood, plasma, saliva, urine and milk.

K-One technology pictogram

Cost-effectiveness

Save up to 30x in ligand consumption, by working with the optimal ligand density for your assay.

Reports pictogram

Compatible with capture systems

Integrate seamlessly with capture systems such as streptavidin, protein A/G, anti‑Fc, and anti‑Fab.

Surface Plasmon Resonance sensorgram pictogram

Rigorous quality process

From AuNP manufacturing to K‑One functionalization, bioconjugation, and large‑scale production — every step follows strict quality procedures.

Our working process

01

EN ATTENTE DE CLAUDE

02

03


04

05


Reach out to us!

Curious about how our K-One gold bioconjugates can bind with your current needs?

FAQ

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Suspendisse varius enim in eros elementum tristique.

How do you optimize antibody pairing for LFA development?
  • Pre-functionalization of SPR sensor chips using K-One® surface chemistry, specifically customized to your applications

  • Optimal ligand immobilization following Kimialys' proprietary protocol

  • In-house biomolecular interaction analysis with our own SPRi/SPR platforms

  • Reliable access to binding and kinetics data, complemented by high-quality reports and presentations, offering actionable insights

Binding interactions screening and epitope binning

We harness both our expertise in SPRi and proprietary K-One® technology on chip to swiftly identify and rank both desired and undesired binding interactions among numerous candidates. This ensures our customers receive consistent and reliable results, accelerating their pursuit of new therapeutics.

We can immobilize any ligands:

  • Antibodies

  • Nanobodies

  • Small molecules

  • Proteins

  • DNA/RNA

  • Whole cells

  • Peptides

  • Aptamers

  • And more...

Our results are consistent and reliable for any complex biological matrices:

  • Plasma

  • Serum

  • Blood

  • Stem cell supernatant

  • Hybridoma supernatant

  • And more...

Kinetics characterization

Reliable measurement of kinetic constants is pivotal for the development of new therapeutics. Leveraging our proprietary K-One® technology, we stand out in the SPR landscape by delivering precise characterization analysis for all biologics and compounds.

Kinetics measured:

  • Affinity (KD)

  • Binding rate constants (kon, koff)

  • Avidity

How do you optimize antibody for LFA development?
  • Pre-functionalization of SPR sensor chips using K-One® surface chemistry, specifically customized to your applications

  • Optimal ligand immobilization following Kimialys' proprietary protocol

  • In-house biomolecular interaction analysis with our own SPRi/SPR platforms

  • Reliable access to binding and kinetics data, complemented by high-quality reports and presentations, offering actionable insights

Binding interactions screening and epitope binning

We harness both our expertise in SPRi and proprietary K-One® technology on chip to swiftly identify and rank both desired and undesired binding interactions among numerous candidates. This ensures our customers receive consistent and reliable results, accelerating their pursuit of new therapeutics.

We can immobilize any ligands:

  • Antibodies

  • Nanobodies

  • Small molecules

  • Proteins

  • DNA/RNA

  • Whole cells

  • Peptides

  • Aptamers

  • And more...

Our results are consistent and reliable for any complex biological matrices:

  • Plasma

  • Serum

  • Blood

  • Stem cell supernatant

  • Hybridoma supernatant

  • And more...

Kinetics characterization

Reliable measurement of kinetic constants is pivotal for the development of new therapeutics. Leveraging our proprietary K-One® technology, we stand out in the SPR landscape by delivering precise characterization analysis for all biologics and compounds.

Kinetics measured:

  • Affinity (KD)

  • Binding rate constants (kon, koff)

  • Avidity

How do you optimize antibody pairing for LFA development?
  • Pre-functionalization of SPR sensor chips using K-One® surface chemistry, specifically customized to your applications

  • Optimal ligand immobilization following Kimialys' proprietary protocol

  • In-house biomolecular interaction analysis with our own SPRi/SPR platforms

  • Reliable access to binding and kinetics data, complemented by high-quality reports and presentations, offering actionable insights

Binding interactions screening and epitope binning

We harness both our expertise in SPRi and proprietary K-One® technology on chip to swiftly identify and rank both desired and undesired binding interactions among numerous candidates. This ensures our customers receive consistent and reliable results, accelerating their pursuit of new therapeutics.

We can immobilize any ligands:

  • Antibodies

  • Nanobodies

  • Small molecules

  • Proteins

  • DNA/RNA

  • Whole cells

  • Peptides

  • Aptamers

  • And more...

Our results are consistent and reliable for any complex biological matrices:

  • Plasma

  • Serum

  • Blood

  • Stem cell supernatant

  • Hybridoma supernatant

  • And more...

Kinetics characterization

Reliable measurement of kinetic constants is pivotal for the development of new therapeutics. Leveraging our proprietary K-One® technology, we stand out in the SPR landscape by delivering precise characterization analysis for all biologics and compounds.

Kinetics measured:

  • Affinity (KD)

  • Binding rate constants (kon, koff)

  • Avidity

What factors impact the accuracy of an LFA test?
  • Pre-functionalization of sensor chips using K-One® surface chemistry, specifically customized to your applications and analytical platforms

  • Supply of batches of pre-functionalized sensor chips + ligand immobilization protocol and reagent

Our pre-functionalization technology is compatible with all gold-based sensors.

For companies looking to manage their own analyses, yet eager to leverage our expertise in chip functionalization and our proficiency in tackling complex analytical challenges.

We provide custom pre-functionalized sensor chips, specifically designed for your ligands, analytical platform, and applications, ensuring that your analyses run smoothly and effectively.

Gold-based sensor types:

  • For common SPR and SPRi platforms: Biacore, Horiba...

  • Other SPR-based biosensors: LSPR, Fiber Optic SPR, LR-SPR...

  • For chip-based diagnostic applications: electrochemical biosensors, QCM...

K-One® technology licensing

Our K-One® surface chemistry technology is available for licensing, offering the opportunity to integrate it within your own production environment and standards.

Still have a question ?

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Suspendisse varius enim in eros elementum tristique.

Contact us